TUNER ICON

Waveguide Components: Power Load

In industrial microwave heating systems water loads are designed to absorb microwave power directly into a high loss fluid medium, usually water. Water loads (dummy loads) are compact sized and show high power absorption capacity. Typically water loads are used in combination with a circulator.

Type

Frequency

[MHz]

VSWR

Power

[kW]

Cooling water

[°C]

water flow

[l / min]

Flange

MW1011E-260DF

2450 ± 25

< 1.15

20

20 ± 5

20

UDR 22

MW1002E-260EC

2450 ± 25

< 1.15

6,5

20 ± 5

3

UDR 26

MW1010E-260FD

2450 ± 25

< 1.15

6,5

20 ± 5

3

UDR 32

MW1018E-230CD

872 - 968

< 1.08

100

20 ± 5

0.8 per kW

UDR 9

print/drucken